Tecumseh Silent/New Silent condensing units
condensing unit Tecumseh THB 4419 YH R134a, 230V-1-50Hz
Order no.: 1083018
Serial number: 4084133125
Q0 at KM: | R134a |
Range: | Medium/High pressure range |
Voltage: | 220-240V/1Ph/50Hz |
Q0 at KM: | R134a |
Q0 (Watt) at t0 +15 °C: | 550 |
Q0 (Watt) at t0 +5 °C: | 404 |
Q0 (Watt) at t0 +/-0 °C: | 338 |
Q0 (Watt) at t0 -5 °C: | 278 |
Q0 (Watt) at t0 -10 °C: | 224 |
Q0 (Watt) at t0 -15 °C: | 176 |
Q0 (Watt) at t0-20 °C: | 135 |
Pe (Watt): | 154 |
Current consumption A max.: | 2.00 |
Sound power db(A): | 57 |
Range: | Medium/High pressure range |
Voltage: | 220-240V/1Ph/50Hz |
Accessories/Spare Parts
Beskrivelse
Lieferumfang
Verflüssigungssatz mit Verdichter, ventilatorbelüftetem Verflüssiger mit Schutzgitter, Saug- und Flüssigkeitsabsperrventilen. Öl-Betriebsfüllung, Stickstoff-Schutzgasfüllung, Einphasen- Wechselstromausführungen mit kompletter elektrischer Ausrüstung und Kabel. Drehstromausführung mit internem Wicklungsschutz, jedoch ohne Schaltkasten, Schütz und Kabel.
R134a | R449A | |||
Nominalbedingungen | Mittel-/Hochdruckbereich | Nominalbedingungen | Mittel-/Hochdruckbereich | |
Umgebungstemperatur/Unterkühlung | 32 °C / 3 K | Umgebungstemperatur/Unterkühlung | 32 °C / 3 K | |
Sauggastemperatur | 20 °C | Sauggasüberhitzung | 20 °C | |
Leistungsaufnahme bei t0 | -10 °C | Leistungsaufnahme bei t0 | -10 °C | |
R452A | ||||
Nominalbedingungen | Niederdruckbereich | Mittel-/Hochdruckbereich | ||
Umgebungstemperatur/Unterkühlung | 32 °C / 3 K | 32 °C / 3 K | ||
Sauggastemperatur | 20 °C | 20 °C | ||
Leistungsaufnahme bei t0 | -35 °C | -10 °C |